Tag Archive for: Imaging

Posts

Guideline of Guidelines: Imaging of Localized Prostate Cancer

Guidelines Localised Prostate Cacner

 

Introduction

In the era before the widespread adoption of PSA screening for prostate cancer, most incident cases were already advanced stage. Because treatment options, such as surgery or radiation, are thought mainly to benefit patients with localised disease, prostate cancer imaging was necessary before treatment of almost all patients. However, in the PSA era >90% of incident cases are localised, making the need for routine imaging with CT, MRI, or bone scan obsolete [1]. Numerous studies show a relatively low rate of positive staging imaging in low- and intermediate-risk patients. Recognising these trends, several professional societies issued prostate cancer imaging guidelines in the mid-1990s in an effort to curb the overuse of imaging. However, despite these longstanding guidelines, a great number of patients undergo improper imaging [2]. Given how stubborn this problem has been to eradicate, there has been a renewed interest in finding ways to decrease unnecessary imaging, including a Physician Quality Reporting System (PQRS) quality measure and a highlighting of the problem in the ‘Choosing Wisely’ campaign [3-5]. In addition to the guidelines regarding the staging of incident prostate cancer, some groups have also presented guidelines on the use of imaging to follow men with advanced disease [6]. The purpose of the present article is to summarise the main points from multiple professional society guidelines on imaging in prostate cancer to help clarify when patients with prostate cancer should be imaged and with which modalities.

Prostate Cancer Key Points

Article of the Week: Nerve-sparing surgery – In vivo periprostatic nerve tracking using MPM in a rat model

Every Week the Editor-in-Chief selects an Article of the Week from the current issue of BJUI. The abstract is reproduced below and you can click on the button to read the full article, which is freely available to all readers for at least 30 days from the time of this post.

If you only have time to read one article this week, it should be this one.

Real-time in vivo periprostatic nerve tracking using multiphoton microscopy in a rat survival surgery model: a promising pre-clinical study for enhanced nerve-sparing surgery

Matthieu Durand***, Manu Jain*, Amit Aggarwal, Brian D. Robinson*‡, Abhishek Srivastava*, Rebecca Smith, Prasanna Sooriakumaran§, Joyce Loefer**, Chris Pumill††, Jean Amiel**, Daniel Chevallier**, Sushmita Mukherjee† and Ashutosh K. Tewari*

 

*Department of Urology, Department of Biochemistry, Department of Pathology and Laboratory Medicine, Weill Medical College of Cornell University, New York-Presbyterian Hospital, New York, NY, ††Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA, §Surgical Intervention Trials Unit, University of Oxford, Oxford, UK, ¶Karolinska Institute, Stockholm, Sweden, and **Department of Urology, Hopital Archet 2, Centre Hospitalier Universitaire de Nice, University of Nice Sophia-Antipolis, Nice, France

 

Read the full article
OBJECTIVES

To assess the ability of multiphoton microscopy (MPM) to visualise, differentiate and track periprostatic nerves in an in vivo rat model, mimicking real-time imaging in humans during RP and to investigate the tissue toxicity and reproducibility of in vivo MPM on prostatic glands in the rat after imaging and final histological correlation study.

MATERIALS AND METHODS

In vivo prostatic rat imaging was carried out using a custom-built bench-top MPM system generating real-time three-dimensional histological images, after performing survival surgery consisting of mini-laparotomies under xylazine/ketamine anaesthesia exteriorising the right prostatic lobe. The acquisition time and the depth of anaesthesia were adjusted for collecting multiple images in order to track the periprostatic nerves in real-time. The rats were then monitored for 15 days before undergoing a new set of imaging under similar settings. After humanely killing the rats, their prostates were submitted for routine histology and correlation studies.

RESULTS

In vivo MPM images distinguished periprostatic nerves within the capsule and the prostatic glands from fresh unprocessed prostatic tissue without the use of exogenous contrast agents or biopsy sample. Real-time nerve tracking outlining the prostate was feasible and acquisition was not disturbed by motion artefacts. No serious adverse event was reported during rat monitoring; no tissue damage due to laser was seen on the imaged lobe compared with the contralateral lobe (control) allowing comparison of their corresponding histology.

CONCLUSIONS

For the first time, we have shown that in vivo tracking of periprostatic nerves using MPM is feasible in a rat model. Development of a multiphoton endoscope for intraoperative use in humans is currently in progress and must be assessed.

Read more articles of the week

Microwave ablation of a small cortical renal tumour – an unexpected adverse outcome

Percutaneous ablation therapies have become an increasingly important treatment option for smaller volume renal tumours. Microwave ablation (MWA) appears to have significant advantages over radiofrequency ablation (RFA) in terms of treatment times and achievable ablation zone volumes. We report the case of a fit 71 year old gentleman with a 17mm slow-growing cortical lower pole renal carcinoma. Given the small volume nature of the tumour, MWA was used instead of cryoablation (CRA) so as to avoid the potential need for multiple cryoprobes. The tumour was successfully treated with MWA with no immediate post-operative complications. On day 7, the patient returned with flank pain and CT confirmed a pelvi-calyceal leak requiring retrograde stenting. Unexpectedly, at five months, a follow-up CT indicated global hypoperfusion. This was confirmed with a MAG-3 renogram showing only 12% contribution to overall function. To date, there have been few reports of microwave ablation of renal tumours. This small, cortical renal tumour would have been expected to undergo straightforward ablation treatment. The subsequent functional demise of the kidney was unexpected in this case. The mechanism of global renal injury remains unclear and more research regarding ablation physiology and dosimetry is required.

Authors: Ingram, Liam ; Hookway, Max; Breen, David
Corresponding Author: Ingram, Liam

 

Introduction
The percutaneous treatment of renal tumours by ablation therapies is now increasingly accepted as a useful therapeutic option. Currently the routinely available options are cryoablation (CRA) or thermal ablation using either radiofrequency (RFA) or microwave (MWA) technology. Traditionally, RFA has been the mainstay of treatment causing targeted cellular death via coagulative necrosis. Whilst RFA has a relatively well documented efficacy, microwave ablation has great potential to overcome some of the disadvantages of RFA. The main theoretical advantages are in terms of ablation zone volumes achieved (1, 2), time efficacy and there being no requirement for grounding pads (3, 4).
Each technology has a specific mode of tissue ablation and hence treated tissue characteristics are an important consideration in this case. For microwave ablation the important physical features are relative permeability and effective conductivity (3). For the kidney, high renal perfusion rates can compromise treatment by yielding inconsistent, geometrically variable ablation zones (3, 5). These effects are particularly evident close to larger peripelvic vessels. Microwave technology has great potential here due to its rapid tissue heating characteristics; however, accurate treatment dosimetry still remains an issue similar to RFA.
There is a relative paucity of literature regarding microwave ablation of renal tumours. A literature search has found 3 small studies showing preliminary data regarding microwave ablation of small renal tumours. The results are mixed, with 2 studies showing good technical outcomes and few complications (6, 7) and the third showing a poor technical outcome with associated intra-operative and post-operative complications as high as 20 and 40%, respectively (8).

Case report
The patient was referred from another hospital for minimally invasive, image-guided biopsy and ablation given the small but solid nature of the lower pole cortical mass.
He was 71 and previously fit and well, with no significant past-medical history other than a single episode of atrial fibrillation 14 years ago. He was not taking any medication and was symptom free.
The lesion was 17mm in size and peripheral in the cortex of the lower pole of the right kidney (Figure 1).

fig11

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1. Portal venous phase CT confirming a solid but hypovascular tumour towards the lower pole of the right kidney.

For the last 3 ½ years CRA rather than RFA has been the mainstay of small renal tumour ablation at our institution. But, given the small nature of the tumour and benefit of a single probe and single site treatment, MWA was agreed. The patient was given pre-operative prophylactic intravenous antibiotics (metronidazole and cefuroxime) 1 hour before the procedure. He was positioned prone under general anaesthetic, and 2 CT guided 18G core biopsies of the lesion were taken. A single stick microwave probe was placed within the lesion under CT guidance. Position was confirmed and microwave ablation was performed. The first cycle was for 3mins 28secs at 180W followed by a 1.5cm draw back and second cycle of 4 mins at 180W with subsequent track ablation.
There were no immediate complications. The patient was sent back to the ward and discharged the following day. Histology of his biopsies showed low grade nuclear features consistent with a partly cystic well differentiated clear cell carcinoma.
On day 7 post-procedure, the patient was re-admitted due to increasing right flank pain. He underwent CT of his abdomen and pelvis with arterial, portal venous and delayed phases (5 mins) being obtained. These showed an adequate, wedge-shaped, non-enhancing ablation zone (Figure 2).The 5 minute delayed study however confirmed free leakage from the lower pole calyx with a moderate retroperitoneal urinoma. On the next day the patient underwent cystoscopic placement of a retrograde ureteric stent to divert the calyceal urine leakage.

fig21

 

 

 

 

 

 

 

 

 

 

 

Figure 2. Portal venous phase CT at day 7 post-procedure showing adequate ablation site and urinoma.

A repeat CT at 1 month showed resolution of the urinoma with no further leak. Again the lesion appeared well treated with a wedge-shaped area of non-enhancement, Figure 3.

fig31

 

 

 

 

 

 

 

 

 

 

Figure 3. Wedge of non-enhancement of ablation zone on portal venous phase CT 1 month post-procedure. Ureteric stent in situ.

At 5 months post-treatment a further follow-up CT scan demonstrated globally diminished perfusion of the right kidney (Figure 4). This was confirmed by a MAG3 renogram which showed only 12% of the total function attributable to the right kidney.

Figure41

Figure 4. Global hypoperfusion of the right kidney seen on portal venous phase CT at 5 months post-procedure.

Discussion
MWA offers significant theoretical benefits over RFA in terms of reduced treatment time, ablation volumes achieved and possibly more predictable treatment geometry. In this case, the small cortical tumour was appropriately treated as evidenced by the typical wedge-shaped ablation zone. With hindsight the first station of the probe was likely in too close a proximity to the lower pole calyx. It could also be argued that the 2 station treatment of 3 minute 28 secs at 180W followed by a further 4 minutes at 180 W peripherally in the cortex represented local over-treatment. But the ablation zone at 7 days and at 1 month suggests that this was not the case and that the resultant ablation zone was only adequate for the tumour ablation undertaken. Even if the calyceal injury could have been avoided by rather more ‘cortical’ positioning of the probe, the propensity for microwave ablation to cause pelvicalyceal injury in this case is striking and more so than might have been expected with image-guided cryoablation. In fact this observation has been confirmed by in vivo porcine studies where thermal based RFA was found to incur pelvicalyceal injury much more readily than CRA for the same probe positioning and ablation zone volumes (9, 10).
The clear benefit of ablation is to offer a more targeted treatment whilst maintaining overall renal function. The unexpected procedural outcome here is the subsequent delayed global hypoperfusion and hence loss of function of the kidney at 4-5 months. This suggests that microwave energy deposition within the kidney may have a greater propensity to cause a more diffuse and non-target renal injury.
The key issue in this case is treatment dosimetry and to date little or no data is available on this issue from MWA manufacturers. Whilst the ablation zone achieved in this case was only adequate to ablate the target tumour, the mechanism of the subsequent functional demise of the kidney remains unclear but likely related to a diffuse microwave heating effect. There is clearly a requirement for further in vivo MWA dosimetry clarification, likely using a porcine renal model.

References
1. Laeseke, P.F., et al. Microwave ablation versus Radiofrequency ablation in the
kidney: High-power triaxial antennas create larger ablation zones than
similarly sized internally cooled electrodes. JVIR. 2009 Sep; 20(9): 1224-9.
2. Clark, P.E., Woodruff, R.D., Zagoria, R.J., Hall, M.C. Microwave ablation of renal parenchymal tumours before nephrectomy: phase I study. AJR AM J Roentgenol. 2007 May;188(5):1212-4
3. Brace, C.L. Radiofrequency and microwave ablation of the liver, lung, kidney and bone: What are the differences? Curr Probl Diagn Radiol. 2009 May-Jun; 38(3):135-143
4. Simon, C. et al. Microwave Ablation: Principles and Applications. Radiographics. 2005 Oct;25: S69-S83
5. Moore, C., et al. Effects of microwave ablation of the kidney. J Endourol. 201 Mar;24(3)439-44
6. Carrafiello, G., et al. Single-antenna microwave ablation under contrast-enhanced ultrasound guidance for treatment of small renal cell carcinoma: preliminary experience. Cardiovasc Intervent Radiol. 2009 Apr; 33(2): 367-74.
7. Liang, P., et al. Ultrasound guided percutaneous microwave ablation for small renal caner: initial experience. J Urol. 2008 Sep; 180(3):844-8
8. Castle, S.M., Salas, N., Leveillee, R.J. Initial experience using microwave ablation therapy for renal tumour treatment: 18-month follow-up. Urology. 2011 Apr; 77(4):792-7
9. Janzen, N. et al. The effects of intentional cryoablation and radiofrequency ablation of renal tissue involving the collecting system in a porcine model. J Urol. 2005 Apr;173(4):1368-74.
10. Brashears, J. et al. Renal ablation and radio frequency ablation: an evaluation of worst case scenarios in a porcine model. J Urol. 2005 Jun;173(6):2160-5.

 

Date added to bjui.org: 16/11/2012
DOI: 10.1002/BJUIw-2012-065-web

 

© 2024 BJU International. All Rights Reserved.